Noise Criteria (NC), Background Noise and Room Acoustics Testing

OSAT provides independent field measurements of background sound, mechanical-system noise and room acoustic performance for completed and occupied facilities. These measurements can support commissioning, acceptance, diagnostic investigations and evaluation of corrective work.

Noise Criteria (NC) testing

Noise Criteria (NC) curves evaluate indoor background sound using octave-band sound pressure levels. A single A-weighted level does not describe the distribution of energy across frequency bands; spaces with similar dBA levels can differ substantially in acoustic character. ASA/ANSI S12.2-2026 provides methods based on A-weighted level and NC curves for representative steady HVAC noise. The applicable edition and criterion should be established from project documents.

NC, RC and other room noise descriptors

NC, Room Criteria (RC), Room Noise Criteria (RNC) and overall dBA levels are not interchangeable. The appropriate descriptor depends on the governing specification and noise characteristics. Older specifications may reference earlier editions or other methods. Tonal, intermittent or low-frequency conditions may warrant additional frequency and time-history analysis rather than reliance on a single rating.

HVAC and mechanical background noise

Measurements may address air handling units, fan-coil units, diffusers, ductwork, pumps, chillers, ventilation equipment and other building services. Operating modes, equipment loads and occupancy conditions should be documented. Comparative testing can assess whether a mechanical modification has reduced sound under comparable conditions.

Reverberation time (RT60) and room acoustic performance

Reverberation describes how sound decays in a room after excitation stops. Field reverberation measurements may report T20 or T30 estimates of a 60 dB decay, depending on the available decay range and applicable method. ISO 3382-2 addresses ordinary rooms; other parts of ISO 3382 address different applications. Reverberation is distinct from sound isolation and background noise. Laboratory material absorption ratings such as NRC do not establish installed room reverberation.

Typical applications

  • Hotels, hospitals and patient consultation rooms.
  • Schools, classrooms, lecture halls and conference rooms.
  • Recording studios, broadcast facilities and critical listening rooms.
  • Commercial offices, meeting rooms and other occupied facilities.

What a field report can include

Depending on the agreed scope, reporting can document octave-band spectra, overall sound levels, applicable noise criteria, room decay measurements, operating conditions, measurement limitations and comparison with specified requirements. See octave-band and FFT analysis, speech intelligibility testing and reports and deliverables.

Request a room acoustics or background noise testing proposal.